Vacutainer Blood Collection ESR Tube

Payment Type: L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,EXW,FCA,CPT,CIP
Min. Order: 1 Carton
Delivery Time: 7 Days

Basic Info


Type: Vacuum Blood Tube & Blood Bag

Certification: ISO13485

Ethylene Oxide Sterilization: Ethylene Oxide Sterilization

Quality Guarantee Period: Two Years

Specification: 13×75mm

Volume: 1.6ml/2.4ml

Additive: 3.8% Sodium Citrate

Qty/PK(Glass)/(PET): 1800pcs


Additional Info


Packaging: export package

Brand: UMS

Transportation: Ocean,Land,Air

Place of Origin: China

Port: Jinan,Qingdao,Shanghai


Product Description

Vacutainer Blood Collection ESR Tube


13×75mm ESR Tube is specially used in blood collection and anticoagulation for Automated Erythrocyte Sedimentation Rate Analyzers sedimentation rate test with the mixing ratio of 1 part sodium citrate to 4 parts blood, by Westergren method.


9×120mm ESR Tube is applicable to various Automated Erythrocyte Sedimentation Rate Analyzers. Due to little volume and negative pressure inside the tube, it needs some time for blood collection. Do patiently wait until blood stops flowing into the tube. Then completely mix the anticoagulation and additive by turning the tube upside down for 6-8 times, Inappropriate mixing will cause hemolysis, coagulation or blood bubble and influence the test result.


PRODUCT DESCRIPTION
Item No. Specification Volume Additive Qty/PK(Glass) Qty/PK(PET)
UMS016NC 13×75mm 1.6ml 3.8% Sodium Citrate 1800 1800
UMS024NC
13×75mm 2.4ml 3.8% Sodium Citrate 1800 1800

Item No. Specification Volume Additive Qty/PK(Glass)
UMS0128NC Φ9×120mm 1.28ml 3.8% Sodium Citrate 1800


ESR Fast Detector

● Main Features:
○ Better compatibility compared with Westergren method.
○ A safe, reliable and airtight operation during the whole process from blood collection to test, free of biological contamination.
○ Designed with spirit level of patent technology, which ensures the detector horizontal and aclinic.
○ 10 channels, synchronous operation allowed.
○ Only 30 minutes needed for reading, easy and fast.
○ Stainless steel soleplate with silicagel cushion on, which will avoid any noise or breakage when the ESR tube being placed.

● How to Use:
○ Carry out the venous blood collection according to standard requirements with 9x120mm ESR vacuum tube.
○ Immediately invert the tube at 180 degrees for 6-8 times to achieve thorough mixing, which will avoid hemolysis, clotting or blood bubble.
○ At the room temperature of around 20℃,vertically place the ESR tube containing blood sample onto the detector, note down the starting
time and relevant numbers. Keep the detector still for 30 minutes and then read the millimeter of erythrocyte sedimentation.
○ Detailed reading method: Keep it stable for 30min, align the plasma concave in ESR tubes to the zero scare of the detector. Then, read the
data by aligning the upper surface of erythrocyte to the scale on the detector. (See as the schematic diagram)
● Notice:
○ Before operation, the ESR fast detector should be put on a steady platform and adjusted to be horizontal with knobs below the soleplate.
○ The ESR tubes should be kept vertical during the whole sedimentation process, angle of inclination should not be more than 3°. Orelse, the
testing result will be of large deviation.
○ Keep the room temperature at 20±5℃, sedimentation time 30±2min.

faster